Diesel Transfer Pump Unit with CE Approval (ZYB80-13A)

Product Details
Customization: Available
Warranty: 12 Months
Flow Rate: 40lpm
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
46
Year of Establishment
2018-03-16
  • Diesel Transfer Pump Unit with CE Approval (ZYB80-13A)
Find Similar Products

Basic Info.

Model NO.
ZYB80-13A
Type
Self-priming Oil Pump
Drive
Electric
Performance
Automatic
Package
L×w×h (Cm):41.5×35×32
Lead Time
20 Days
OEM/ODM
Available
Transport Package
1set/CTN
Specification
CE
Trademark
Yiben
Origin
Wenzhou, China
HS Code
8413110000
Production Capacity
50000 Pcsevery Month

Product Description

Model No.: ZYB80-13A
(pump+4m delivery hose+manual oil nozzle+120L flowmeter)

Product introduction:The ZYB series oil pump unit is used for pumping light oils such as diesel or kerosene for vehicles, construction sites, farms or for other fuel powered equipment.

Technical Parameters:
Model

ZYB80-13A

Complete Pump Set

pump+4m delivery hose+manual oil nozzle+120L flowmeter

Rated Voltage

   AC220V or AC110V

Rated Power

          550W

Motor Turn Speed

          1400r/min

Pump Flow Rate

(50-80)L/min

Meter flowrate

(20-120)L/min

Suction Lift

3-5m

Head Lift

5-10m

In-out

In BSPT1",Out BSPT1"

Flow Meter Digit

4 Digit,Max.9999.9 Liter,
8 Digit Accumulated

 

Environment condition:

Temperature: -25ºC---+55ºC

Relative Humidity: 30%--90%

High Atmospheric Pressure:86Kpa--106Kpa



Malfunction Diagnosis & Resolution:

Common Troubleshooting

Fault Apperance

Main Reason

Fault Resolution

Motor does not turn

1.The power cable is not plugged in

1.Check the electric cable

2.The motor has jammed

2.Replace the motor

3.Capacitor failure

3.Replace capacitors

Motor turns, but no oil output

1.Suction side not submerged in oil

1.Check the oil suction hose/pipe

2.Vanes worn or gear damaged

2.Replace vanes or gear

Abnormal metering or no meter output

Computation swing tray has broken

Replace the computation swing tray

Little oil-output

Plugged strainer

Clean the strainer


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier